Sunlight and Weathering Test Chamber
HY-720
Mainly used for lightfastness and weatherfastness testing in color fastness tests. It can also conduct lightfastness testing and light aging testing for a variety of materials, including paints, pigments, coatings, rubber, plastics, wood flooring, and paper. It provides reliable technical support for the research and development, quality control, and performance verification of products in industries such as textiles, chemicals, building materials, and packaging.
Quantity:
HY-720 Sunlight and Weathering Test Chamber
Standards:
ISO105-B02, GB/T8427, GB/T15102-2006, GB/T14576, GB/T15104-2006, GB/T8430, AATCC TM16, ISO105-B04
Product Introduction:
Standards:
ISO105-B02, GB/T8427, GB/T15102-2006, GB/T14576, GB/T15104-2006, GB/T8430, AATCC TM16, ISO105-B04
Product Introduction:
Used for testing lightfastness and weatherfastness in color fastness testing. It can also be used for lightfastness testing and light aging testing of paints, pigments, coatings, rubber, plastics, wood flooring, paper, and other materials.
Technical Parameters:
1. Test Chamber Temperature Control Range: (20~50)℃; Accuracy: ±2℃
2. Test Chamber Humidity Control Range: (15~95)%RH; Accuracy: ±5%RH
3. Test Time Control Range: 0~9999:59 (h:min); Accuracy: ±1min
4. Irradiance Control Range:
(0.80~1.60)W/m2/420nm; Accuracy: ±0.02W/m2/420nm
(25-60)W/m2/300-400nm; Accuracy: ±2W/m2/420nm
(300-650)W/m2/300-800nm Accuracy: ±10W/m²/420nm Digital setting, automatic compensation
5. Xenon lamp light source:
a. Xenon arc lamp rated power: 1.4kW;
b. Color temperature: 5500K~6500K;
6. Sample:
a. Sample holder rotation speed: 5rpm; Accuracy: ±3 seconds
b. Sample clamp distribution diameter: 286mm
c. Size and number of sample clamps that can be installed:
National Standard American Standard (optional)
Sample clamp size 208mm×48mm 208mm×92mm
Maximum sample size 122mm×45mm 122mm×90mm
Maximum exposure area 110mm×33mm 110mm×50mm
Maximum number of samples that can be installed 13 6
Maximum sample size 122mm×45mm 122mm×90mm
Maximum exposure area 110mm×33mm 110mm×50mm
Maximum number of samples that can be installed 13 6
d. Separate timing for each sample clamp: Range: 0min~9999:59 (h:min); Accuracy: ±1 min
e. Sample thickness: ≤3 mm
7. Standard Black Label Thermometer (BST) range: (30~75)℃; resolution: 0.1℃, accuracy: ±2℃
e. Sample thickness: ≤3 mm
7. Standard Black Label Thermometer (BST) range: (30~75)℃; resolution: 0.1℃, accuracy: ±2℃
Or optional Black Label Thermometer (BPT) range: (30~70)℃, resolution: 0.1℃, accuracy: ±2℃
8. 7-inch touchscreen operation
9. Power supply: AC220V±10%, (voltage regulator can be selected according to the actual power grid), 50Hz, rated power: 5.5 KW.
8. 7-inch touchscreen operation
9. Power supply: AC220V±10%, (voltage regulator can be selected according to the actual power grid), 50Hz, rated power: 5.5 KW.
10. Dimensions: 1130mm×750mm×1895mm (L×W×H)
11. Weight: Approximately 400kg
11. Weight: Approximately 400kg